Key Features
 
 
 
Lowest peak track force* (N)
 
*Data on file. Bench test results may not necessarily be indicative of clinical performance. Test performed by and data on file at Sahajanand Medical Technologies Ltd. Testing performed on Pipit (PTCA Balloon Dilatation Catheter – Non-Compliant) 3.50mmX 15mm, NC Emerge (3.50mmX 15mm), Accuforce NC (3.50mmX 15mm), NC Trek (3.50mmX 15mm)
 
Best-in-class pushability*
 
 
Efficiency in transfer of Push Force from hub to tip (in %)
 
*Data on file. Bench test results may not necessarily be indicative of clinical performance. Test performed by and data on file at Sahajanand Medical Technologies Ltd. Testing performed on Pipit (PTCA Balloon Dilatation Catheter – Non-Compliant) 3.50mmX 15mm, NC Emerge (3.50mmX 15mm), Accuforce NC (3.50mmX 15mm), NC Trek (3.50mmX 15mm)
 
Low rewrap profile
 

Average Max force to Re-cross (N)

 

Best-in-class shape memory profile due to Multi-layered balloon material and Improved manufacturing process

 
 
Hydrophilic coating is applied on the folded balloon which leads to coated- uncoated balloon surface.
  • During the folded state, hydrophilic coating helps in trackability
  • During inflation, uncoated portion helps in anchoring the balloon and prevents slippage
 
*Data on file. Bench test results may not necessarily be indicative of clinical performance. Test performed by and data on file at Sahajanand Medical Technologies Ltd. Testing performed on Pipit (PTCA Balloon Dilatation Catheter – Non-Compliant) 3.50mmX 15mm, NC Emerge (3.50mmX 15mm), Accuforce NC (3.50mmX 15mm), NC Trek (3.50mmX 15mm)
Low tip entry profile (0.41 mm / 0.016")
 
 
 
Source: Product brochures / marketing collaterals of respective brands
 


 
Kink-resistant shaft

Proximal & distal shaft of balloon had no kinks or lumen collapse at turning sequence 1,2,3,4.

 
Wrap the catheter such that it covers half of the circumference
 
Technical Specifications
Balloon material Multi-layered polyamide
Balloon fold Tri-fold
Hydrophilic coating Selective hydrophilic coating at distal shaft including balloon tip.
Tip entry profile 0.016"(0.41 mm)
Shaft diameter Proximal 1.95F, Distal 2.6F
Catheter length 140 cm
Rapid exchange length 25 cm
Markers on the proximal shaft 90 cm & 100 cm
Maximum recommended guidewire 0.014" (0.36 mm)
Guide catheter compatibility 5F
#KBT compatibility 6F KBT compatible (2 Balloons)
Nominal pressure 12 atm
Rated burst pressure 20 atm (18 atm for 5 mm)
Compliance Chart
Pressure
[atm]
2.00
mm
2.25
mm
2.50
mm
2.75
mm
3.00
mm
3.50
mm
4.00
mm
4.50
mm
5.00
mm
8 1.96 2.18 2.44 2.69 2.88 3.42 3.9 4.35 4.92
10 1.99 2.23 2.48 2.73 2.95 3.46 3.95 4.43 4.96
12 2.02 2.26 2.52 2.76 3.01 3.5 4 4.5 5
14 2.05 2.3 2.56 2.8 3.05 3.54 4.05 4.55 5.07
16 2.08 2.34 2.6 2.83 3.09 3.58 4.1 4.62 5.14
18 2.11 2.38 2.64 2.88 3.13 3.63 4.16 4.69 5.22
20 2.14 2.42 2.68 2.93 3.17 3.67 4.21 4.75 5.28
21 2.15 2.43 2.69 2.94 3.18 3.68 4.22 4.76 5.29
22 2.16 2.44 2.7 2.95 3.19 3.69 4.23 4.77 5.3
23 2.18 2.46 2.72 2.97 3.21 3.71 4.25 4.79 5.32
24 2.2 2.48 2.74 2.99 3.23 3.73 4.27 4.81 5.34
 
 
 
Size Matrix and Ordering Information
Pipit NC
Balloon Sizes
Balloon Lengths (mm)
6 8 10 12 15 20
Balloon Diameter (mm)
2.00 FGNT200006 FGNT200008 FGNT200010 FGNT200012 FGNT200015 Upcoming and Make to order
2.25 FGNT225006 FGNT225008 FGNT225010 FGNT225012 FGNT225015
2.50 FGNT250006 FGNT250008 FGNT250010 FGNT250012 FGNT250015
2.75 X FGNT275008 FGNT275010 FGNT275012 FGNT275015
3.00 X FGNT300008 FGNT300010 FGNT300012 FGNT300015
3.50 X FGNT350008 FGNT350010 FGNT350012 FGNT350015
4.00 X FGNT400008 FGNT400010 FGNT400012 FGNT400015
4.50 X Upcoming and Make to order
5.00 X

#KBT (kissing balloon technique) compatible up to 4 mm diameter

Disclaimer: Pipit NC is a trademark of SMT. Specifications are subject to modification, revision and improvement. Accuforce is a Trademark of Terumo Corporation, Emerge is a trademark of Boston Scientific, NC Trek is a trademark of the Abbott group of companies.Patera Leo is registered trademark of BIOTRONIK AG .